Boiler

Related Information

  • Boiler Ratings and Boiler Load - Alken-Murray

    Boiler Ratings and Boiler Load . The oldest method of rating boilers, still used to rate small boilers, is by horsepower (hp). One horsepower is defined as the ability to evaporate 34.5 lbs of water into steam at 212 deg. F and above. Large boiler capacity is generally given in lbs of steam evaporated per hour, under specified steam conditions.Learn More

  • How to Calculate Gas Consumption in a Gas Boiler Burner?

    Mar 20, 2019 · Step 2. Determine the burner output in BTUs per hour from the appliance sticker or user documentation. The output will be in BTU (for example, 40,000 BTU). Step 3. Divide the BTUs per hour by the fuel energy content. Our burner with the 40,000 BTU per hour output divided by 1,075 equals 37.21 cubic feet of gas per hour.Learn More

  • What is a boiler horsepower [BHP], a unit of power measurement

    One Boiler Horsepower (1BHP) is equal to a bolier thermal output of 33 475 BTU/h (British Thermal Units per Hour) or 9.81055407 kW (Kilowatts). This is the energy rate required to evaporate 34.5 lb (pounds) or 15.648936765 kg (kilograms) of fresh water at 212 °F (degrees Fahrenheit) or 100 °C (Celsius) in one hour …Learn More

  • Unit Conversion--How to Calculate Boiler Horsepower

    5000 lbs of steam / 34.5 = 145 hp boiler 1 horsepower (boiler)= 33445.6 Btu (mean)/hr= 140671.6 calorie/min (thermo)= 140469.4 calorie (mean)/min= 140742.3 calorie (20℃)/min 9.8095x1010 erg/sec= 434107 foot-pound-force/min= 13.1548 horsepower (mech)= 13.1495 horsepower (electric)= 13.3372 horsepower (metric)= 13.1487 horsepower (water)= 9809.5 joule/sec= 9.8095 kilowatt Experts help you calculate boiler …Learn More

  • Department of Labor and Workforce Development | Boilers

    Each automatically fired hot water boiler falling within the terms of N.J.S.A. 34:7-14(a) shall have an automatic low-water fuel cutoff which has been designed for hot water boiler service when such boiler exceeds a heat input of 400,000 BTU per hour except that such low water cut off shall not be required for hot water supply boilers.Learn More

  • CERTIFIED ENERGY MANAGER ® TRAINING PROGRAM

    4. In operating a boiler with dual fuel capability, which is the lowest cost of fuel given the following? Natural gas $4.00/GJ efficiency = 92%, Fuel oil $123/ton efficiency = 88% (42,000 kJ/kg) (A) Natural gas (B) Fuel oil 5. A 1000 square metre building consumes the following amounts of energy per …Learn More

  • convert boiler heating surface to horsepower – Industrial

    Apr 25, 2020 · A common definition of one boiler horsepower is the amount of energy required to produce 34.5 pounds (15.65 kg) of steam per hour at pressure and temperature 0 psig (0 bar) and 212 o F (100 o C) – with feed water at pressure 0 psig and temperature 212 o F. convert boiler heating surface to horsepower – CFBC Boiler …Learn More

  • Steam Capacity Conversion Table | Industrial Controls

    Dec 13, 2010 · Sizing a Boiler Feed Pump Receiver. The receiver tank should be able to hold five minutes worth of condensate for boilers up to 200 BHP and 10 minutes of condensate for boilers over 200 BHP. An additional 33 percent should be added as a safety factor. One BHP (Boiler Horsepower) will produce 0.069 gallons per minute of condensate.Learn More

  • convert boiler heating surface to horsepower – Industrial

    Apr 25, 2020 · A common definition of one boiler horsepower is the amount of energy required to produce 34.5 pounds (15.65 kg) of steam per hour at pressure and temperature 0 psig (0 bar) and 212 o F (100 o C) – with feed water at pressure 0 psig and temperature 212 o F. convert boiler heating surface to horsepower – CFBC Boiler …Learn More

  • AP-42, Appendix A : Miscellaneous Data And Conversion Factors

    Each nominal horsepower of a boiler requires 30 to 35 pounds of water per hour. A horsepower is equivalent to raising 33,000 pounds one foot per minute, or 550 pounds one foot per second. To find the pressure in pounds per square inch of a column of water, multiply the height of the column in feet by 0.434. A-4 EMISSION FACTORS (Reformatted 1 Learn More

  • unit conversion: ton of refrigeration to horsepower - HVAC

    Feb 18, 2005 · Generally speaking the conversion was 12,000 btu/hr to 5.2 hp. There was also a boiler hp conversion that was really different. I think I should be using 1 ton refrig = 12,000 btu/hr = 5.2 hp. Can someone verify this and if you have an idea as to why the boiler hp is a different conversion I'd be interested as well. Thanks.Learn More

  • Boiler Formulas | Johnston Boiler | Top Quality Boiler

    Boiler Horsepower: BHP = (LB/HR*fe)/34.5: Lb/Hr: Pounds per Hour: BHP = 21500 * 1.08 / 34.5: Fe: Factor of Evaporation: BHP = 673Learn More

  • 150 HP Boiler Models | Cleaver-Brooks | York-Shipley

    150 HP is a very commonly requested size in the boiler business. At 150 HP, you get maximum steam or hot water capacity with a minimally sized footprint, a low overall height for plants with overhead restrictions, and a variety of great American manufacturers who produce this size boiler. 150 HP boilers can be purchased in low pressure (15psi) steam, high pressure (150 – 300psi) steam, hot Learn More

  • Convert MBH to Horsepower (boiler)

    Instant free online tool for MBH to horsepower (boiler) conversion or vice versa. The MBH to horsepower (boiler) conversion table and conversion steps are also listed. Also, explore tools to convert MBH or horsepower (boiler) to other power units or learn more about power conversions.Learn More

  • Fuel and Energy Conversion and Equivalence Chart

    Coal 28,000,000/ton 1 Barrel of Oil = 42 Gallons 1 Btu = 252 calories 1 Btu = .293 watt 1 ton of refrigeration = 12,000 Btu/hr 1lb residential garbage = 2,500 Btu 1lb coal = 12,000 Btu 1lb wood = 3,500 Btu 1hp = 746 watts 1hp = 33,479 Btu/hr (boiler)Learn More

  • Btus Per Hour to Boiler Horsepower | Kyle's Converter

    Unit Descriptions; 1 BTU (International Table) per Hour: Approximately 0.293 071 Watts (SI). 1 Horsepower (boiler): The energy rate needed to evaporate 34.5lb of water at 212 °F (100 °C) in one hour.Learn More

  • United States Environmental Protection Agency | US EPA

    PTE (ton/yr) = Engine Capacity (hp) x EF (lb/hp-hr) x 8760 hr x 1 ton/2000 lb Emission Factor 1 (lbs/hp-hr) Default = 0.0015 Default = 0.0015 Process Liquid Fuel (distillate, diesel, etc.) Potential To Emit Calculator for Boilers 2. Assumed PM and PM 2.5 emissions are equal to PM 10 emissions. 2. Assume PM emissions are equal to PM10 emissionsLearn More

  • Wood Disposal Solutions & Recycling | Komar Industries, Inc.

    Horsepower: 180: Peak Tons per Hour: Some of our customers, however, desire to make their wood waste into mulch or boiler fuel. To meet this objective, Komar suggests one of the three solutions below, depending upon your wood waste's metal content. Wood Waste from Cut-Offs.Learn More

  • Boiler Capacity - Engineering ToolBox

    Horsepower (hp) can be converted into lbs of steam by multiplying hp with 34.5. Example - Boiler Horsepower to lbs of Steam Conversion. 200 hp x 34.5 = 6900 lbs of steam per hour. Lbs of steam can be converted to hp by dividing lbs steam per hour by 34.5. Example - Lbs of Steam to Boiler Horsepower Conversion. 5000 lbs of steam / 34.5 = 145 hp boilerLearn More

  • Bulk Material Belt Conveyor Specification

    Capacity: 325 tons per hour Material: Limestone Density: 65 lbs per cubic foot Lump size: 3/8 inch to 0 with a high percentage of fines. 5.0 DESIGN AND MANUFACTURE 5.1 GENERAL 5.1.1 The Belt Conveyors shall be designed and manufactured for heavy-duty, minimum maintenance, outdoor, 24-hour per day paper mill boiler service.Learn More